This document defines what connects to what within the EcoFlow ecosystem.
Can I plug a battery from Model X into Model Y?
| Main Unit | Compatible Extra Batteries | Notes |
|---|---|---|
| Delta 2 | Delta 2 EB | Can technically use Delta Max EB (Capacity display might be buggy). |
| Delta 2 Max | Delta 2 Max EB, Delta 2 EB, Delta Max EB | Highly versatile. Treats Delta 2 EB as a generic expansion. |
| Delta Max | Delta Max EB, Delta 2 Max EB (Limited support) | Delta Max 1600 is incompatible with Delta 2 EB due to discharge rate (1C) risks. |
| Delta Pro | Delta Pro EB | Proprietary Voltage. Cannot use generic Delta batteries. |
| Delta Pro 3 | Delta Pro 3 EB, Delta Pro EB (with adapter) | Backwards compatible with original Pro batteries. |
| Delta 3 Plus / Max | Delta 3 Plus/Max EB, Delta 2/Max EB, Pro 3 EBΒΉ | ΒΉ Requires multi-step adapter chain (see below). |
| River 2 Series | NONE | River 2 series units are not expandable (sealed). |
| River Pro (Old) | River Pro EB | ε°η¨ cable required. |
Hack Note: See
hardware/EXTRA_BATTERY.mdfor how to bypass these limits using the βResistor Hackβ to connect generic 48V batteries to Delta 2 / Delta Max ports.The βBridgeβ Solution: To connect a Delta Pro 3 Extra Battery to a Delta 3 Plus/Max (or Delta 2/Max), you need:
Pro 3 EB->EB Cable->Smart Generator Adapter->XT150 Cable->Main Unit.Power Kit Batteries (2kWh / 5kWh): These are NOT directly compatible with Delta/River units via a simple cable. They require the Power Hub OR the LFP Battery Polarity Adapter (making them a generic 48V source, which then requires the Resistor Hack to feed a Delta unit).
Can I use Solar Panel X with Power Station Y?
Rule of Thumb:
| Unit | Max Voltage (Voc) | Max Input (W) | Connector |
|---|---|---|---|
| River 2 | 30V | 110W | XT60 |
| River 2 Max | 50V | 220W | XT60 |
| River 2 Pro | 50V | 220W | XT60 |
| Delta Mini | 75V | 300W | XT60 |
| Delta (OG) | 65V | 400W | XT60 |
| Delta 2 | 60V | 500W | XT60i |
| Delta Max | 100V | 800W (Dual Port) | XT60i |
| Delta 2 Max | 60V (x2 Ports) | 1000W (500W x2) | XT60i |
| Delta Pro | 150V | 1600W | XT60i (High Voltage) |
| Main Unit | PowerStream (Microinverter) | Alternator Charger (800W) | Notes |
|---|---|---|---|
| Delta Pro 3 | β | β | Alt Charger needs adapter. |
| Delta 3 Plus / Max | β | β | Direct XT150 connection. |
| Delta Pro | β | β (Needs Adapter) | PowerStream needs BKW-DeltaPro cable. STREAM Micro connects via standard MC4/Grid. |
| Delta 2 Max | β | β (Direct XT150) | Best match for Alternator Charger (Fast charge). |
| Delta 2 | β | β (Direct XT150) | Β |
| Delta Max | β | β (Direct XT150) | Β |
| River 2 Series | β | β (Via XT60 adapter) | Alt Charger output (800W) might exceed River input limits! Check specs. |
| STREAM Ultra | β (Integrated) | β (Internal) | All-in-one unit. Can connect to additional DELTA batteries. |
| Device | Bluetooth | Wi-Fi | Matter/HomeKit | Local MQTT (Port 6500) |
|---|---|---|---|---|
| Delta (OG) | β | β | β | β |
| River (OG) | β | β | β | β |
| Delta 2 / Max | β | β | β | β |
| Delta Pro | β | β | β | β |
| River 2 | β | β | β | β |
| Delta Pro 3 | β | β | β (Some regions) | β (New Encryption?) |
| PowerStream | β | β | β (Plug Integration) | β |
| STREAM Micro | β | β | β (OASIS AI) | β |
| STREAM Ultra | β | β | β (OASIS AI) | β |
| Alternator Chg | β | β | β | β |